ERDDAP
Easier access to scientific data |
|
Brought to you by NOAA NMFS SWFSC ERD |
Dataset Title: | Village of Marblehead:water quality station |
Institution: | Village of Marblehead (Dataset ID: obs_14) |
Information: | Summary | License | FGDC | ISO 19115 | Metadata | Background | Make a graph |
Attributes { s { time { String _CoordinateAxisType "Time"; String axis "T"; String calendar "gregorian"; String ioos_category "Time"; String long_name "Time"; String standard_name "time"; String time_origin "01-JAN-1970 00:00:00"; String units "seconds since 1970-01-01T00:00:00Z"; } longitude { String _CoordinateAxisType "Lon"; String axis "X"; String ioos_category "Location"; String long_name "Longitude"; String standard_name "longitude"; String units "degrees_east"; } latitude { String _CoordinateAxisType "Lat"; String axis "Y"; String ioos_category "Location"; String long_name "Latitude"; String standard_name "latitude"; String units "degrees_north"; } chlorophyll_fluorescence { String ioos_category "Unknown"; String long_name "chlorophyll_fluorescence"; String platform "platform"; String units "RFU"; } mass_concentration_of_blue_green_algae_in_sea_water_rfu { String ioos_category "Unknown"; String long_name "phycocyanin_fluorescence"; String platform "platform"; String units "RFU"; } mass_concentration_of_chlorophyll_in_sea_water { String ioos_category "Unknown"; String platform "platform"; String standard_name "mass_concentration_of_chlorophyll_in_sea_water"; String units "kg m-3"; } oxidation_reduction_potential { String ioos_category "Unknown"; String long_name "oxidation_reduction_potential"; String platform "platform"; String units "mV"; } sea_surface_temperature { String ancillary_variables "sea_surface_temperature_gross_range_test sea_surface_temperature_spike_test sea_surface_temperature_rate_of_change_test sea_surface_temperature_flat_line_test sea_surface_temperature_aggregate"; String ioos_category "Temperature"; String platform "platform"; String standard_name "sea_water_temperature"; String units "K"; } sea_surface_temperature_gross_range_test { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "gross_range_test_quality_flag"; Byte valid_max 9; Byte valid_min 1; } sea_surface_temperature_spike_test { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "spike_test_quality_flag"; Byte valid_max 9; Byte valid_min 1; } sea_surface_temperature_rate_of_change_test { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "rate_of_change_test_quality_flag"; Byte valid_max 9; Byte valid_min 1; } sea_surface_temperature_flat_line_test { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "flat_line_test_quality_flag"; Byte valid_max 9; Byte valid_min 1; } sea_surface_temperature_aggregate { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "aggregate_quality_flag"; Byte valid_max 9; Byte valid_min 1; } sea_water_electrical_conductivity { String ioos_category "Salinity"; String platform "platform"; String standard_name "sea_water_electrical_conductivity"; String units "S m-1"; } sea_water_ph_reported_on_total_scale { String ioos_category "Unknown"; String platform "platform"; String standard_name "sea_water_ph_reported_on_total_scale"; String units "1"; } sea_water_specific_conductivity { String ioos_category "Unknown"; String platform "platform"; String standard_name "sea_water_electrical_conductivity_at_reference_temperature"; String units "Unknown"; } platform { String _Unsigned "false"; String cf_role "timeseries_id"; String ioos_category "Unknown"; } } NC_GLOBAL { String cdm_data_type "TimeSeries"; String cdm_timeseries_variables "platform,longitude,latitude"; String Conventions "COARDS,CF-1.7,IOOS-1.2,ACDD-1.3"; String creator_country "USA"; String creator_email "marwater@cros.net"; String creator_institution "Village of Marblehead"; String creator_name "Village of Marblehead"; String creator_sector "gov_municipal"; String creator_type "institution"; String creator_url "https://www.marbleheadohio.org/government/contact/"; String featureType "TimeSeries"; String geospatial_lat_units "degrees_north"; String geospatial_lon_units "degrees_east"; String gts_ingest "false"; String history "2024-11-21T11:31:33Z (source database) 2024-11-21T11:31:33Z https://seagull-erddap.glos.org/erddap/tabledap/obs_14.html"; String id "obs_14"; String infoUrl "http://habs.glos.us/about/"; String institution "Village of Marblehead"; String keywords "at, Chlorophyll, chlorophyll, concentration, Conductivity, conductivity, depth, electrical, fluorescence, in, mass, of, on, Oxidation, oxidation, pH, ph, Phycocyanin, phycocyanin, potential, reduction, reference, reported, scale, sea, Specific, temp, temperature, total, Water, water"; String keywords_vocabulary "GCMD Science Keywords"; String license "The data may be used and redistributed for free but is not intended for legal use, since it may contain inaccuracies. Neither the data contributor, GLOS, NOAA, nor the United States Government, nor any of their employees or contractors, makes any warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, or assumes any legal liability for the accuracy, completeness, or usefulness, of this information."; String naming_authority "org.glos"; String platform "fixed"; String platform_name "Village of Marblehead"; String platform_vocabulary "http://mmisw.org/ont/ioos/platform"; String publisher_country "United States"; String publisher_email "info@glos.org"; String publisher_institution "GLOS"; String publisher_url "https://glos.org"; String sourceUrl "(source database)"; String standard_name_vocabulary "CF Standard Name Table v77"; String summary "Monitoring lake conditions at water treatment plants, remote pump stations, and intakes are an effective Harmful Algae Blooms (“HABs “) early warning system. Between 2014 and 2018, LimnoTech and GLOS worked with the water treatment plant system at Village of Marblehead to bring online the first version of the Lake Erie HABs monitoring network (the “Lake Erie HABs EWS”). In 2017, GLOS, together with Cleveland Water Alliance, LimnoTech, NOAA GLERL and Ohio State University, embarked on a 3-year project funded by the NOAA Ocean Technology Transition project to transition the Lake Erie HABs EWS into a sustainable, operational system.This allows water managers and researchers in the Lake Erie region to have timely and easy access to critical monitoring data during future blooms to help them make informed decisions about activities and resources affected by HABs presence and toxicity."; String title "Village of Marblehead:water quality station"; } }
The URL specifies what you want: the dataset, a description of the graph or the subset of the data, and the file type for the response.
Tabledap request URLs must be in the form
https://coastwatch.pfeg.noaa.gov/erddap/tabledap/datasetID.fileType{?query}
For example,
https://coastwatch.pfeg.noaa.gov/erddap/tabledap/pmelTaoDySst.htmlTable?longitude,latitude,time,station,wmo_platform_code,T_25&time>=2015-05-23T12:00:00Z&time<=2015-05-31T12:00:00Z
Thus, the query is often a comma-separated list of desired variable names,
followed by a collection of
constraints (e.g., variable<value),
each preceded by '&' (which is interpreted as "AND").
For details, see the tabledap Documentation.