ERDDAP
Easier access to scientific data |
|
Brought to you by NOAA NMFS SWFSC ERD |
Dataset Title: | Sandusky Bay buoy:water quality station |
Institution: | BGSU (Dataset ID: obs_79) |
Information: | Summary | License | FGDC | ISO 19115 | Metadata | Background | Make a graph |
Attributes { s { time { String _CoordinateAxisType "Time"; String axis "T"; String calendar "gregorian"; String ioos_category "Time"; String long_name "Time"; String standard_name "time"; String time_origin "01-JAN-1970 00:00:00"; String units "seconds since 1970-01-01T00:00:00Z"; } longitude { String _CoordinateAxisType "Lon"; String axis "X"; String ioos_category "Location"; String long_name "Longitude"; String standard_name "longitude"; String units "degrees_east"; } latitude { String _CoordinateAxisType "Lat"; String axis "Y"; String ioos_category "Location"; String long_name "Latitude"; String standard_name "latitude"; String units "degrees_north"; } air_pressure { String ancillary_variables "air_pressure_gross_range_test air_pressure_spike_test air_pressure_rate_of_change_test air_pressure_flat_line_test air_pressure_aggregate"; String ioos_category "Pressure"; String platform "platform"; String standard_name "air_pressure"; String units "Pa"; } air_pressure_gross_range_test { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "gross_range_test_quality_flag"; Byte valid_max 9; Byte valid_min 1; } air_pressure_spike_test { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "spike_test_quality_flag"; Byte valid_max 9; Byte valid_min 1; } air_pressure_rate_of_change_test { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "rate_of_change_test_quality_flag"; Byte valid_max 9; Byte valid_min 1; } air_pressure_flat_line_test { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "flat_line_test_quality_flag"; Byte valid_max 9; Byte valid_min 1; } air_pressure_aggregate { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "aggregate_quality_flag"; Byte valid_max 9; Byte valid_min 1; } air_temperature { String ancillary_variables "air_temperature_gross_range_test air_temperature_spike_test air_temperature_rate_of_change_test air_temperature_flat_line_test air_temperature_aggregate"; String ioos_category "Temperature"; String platform "platform"; String standard_name "air_temperature"; String units "K"; } air_temperature_gross_range_test { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "gross_range_test_quality_flag"; Byte valid_max 9; Byte valid_min 1; } air_temperature_spike_test { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "spike_test_quality_flag"; Byte valid_max 9; Byte valid_min 1; } air_temperature_rate_of_change_test { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "rate_of_change_test_quality_flag"; Byte valid_max 9; Byte valid_min 1; } air_temperature_flat_line_test { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "flat_line_test_quality_flag"; Byte valid_max 9; Byte valid_min 1; } air_temperature_aggregate { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "aggregate_quality_flag"; Byte valid_max 9; Byte valid_min 1; } battery_voltage { String ioos_category "Unknown"; String long_name "battery_voltage"; String platform "platform"; String units "V"; } chlorophyll_fluorescence { String ioos_category "Unknown"; String long_name "chlorophyll_fluorescence"; String platform "platform"; String units "RFU"; } fluorescent_dissolved_organic_matter { String ioos_category "Unknown"; String long_name "fluorescent_dissolved_organic_matter"; String platform "platform"; String units "RFU"; } fractional_saturation_of_oxygen_in_sea_water { String ioos_category "Dissolved O2"; String platform "platform"; String standard_name "fractional_saturation_of_oxygen_in_sea_water"; String units "1"; } mass_concentration_of_oxygen_in_sea_water { String ioos_category "Dissolved O2"; String platform "platform"; String standard_name "mass_concentration_of_oxygen_in_sea_water"; String units "kg m-3"; } phycocyanin_fluorescence { String ioos_category "Unknown"; String long_name "phycocyanin_fluorescence"; String platform "platform"; String units "RFU"; } sea_surface_temperature { String ancillary_variables "sea_surface_temperature_gross_range_test sea_surface_temperature_spike_test sea_surface_temperature_rate_of_change_test sea_surface_temperature_flat_line_test sea_surface_temperature_aggregate"; String ioos_category "Temperature"; String platform "platform"; String standard_name "sea_water_temperature"; String units "K"; } sea_surface_temperature_gross_range_test { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "gross_range_test_quality_flag"; Byte valid_max 9; Byte valid_min 1; } sea_surface_temperature_spike_test { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "spike_test_quality_flag"; Byte valid_max 9; Byte valid_min 1; } sea_surface_temperature_rate_of_change_test { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "rate_of_change_test_quality_flag"; Byte valid_max 9; Byte valid_min 1; } sea_surface_temperature_flat_line_test { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "flat_line_test_quality_flag"; Byte valid_max 9; Byte valid_min 1; } sea_surface_temperature_aggregate { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "aggregate_quality_flag"; Byte valid_max 9; Byte valid_min 1; } sea_surface_wave_significant_period { String ioos_category "Surface Waves"; String platform "platform"; String standard_name "sea_surface_wave_significant_period"; String units "s"; } sea_water_electrical_conductivity { String ioos_category "Salinity"; String platform "platform"; String standard_name "sea_water_electrical_conductivity"; String units "S m-1"; } sea_water_ph_reported_on_total_scale { String ioos_category "Unknown"; String platform "platform"; String standard_name "sea_water_ph_reported_on_total_scale"; String units "1"; } sea_water_specific_conductivity { String ioos_category "Unknown"; String platform "platform"; String standard_name "sea_water_electrical_conductivity_at_reference_temperature"; String units "Unknown"; } sea_water_turbidity { String ioos_category "Total Suspended Matter"; String platform "platform"; String standard_name "sea_water_turbidity"; String units "1"; } wind_from_direction { String ancillary_variables "wind_from_direction_gross_range_test wind_from_direction_spike_test wind_from_direction_rate_of_change_test wind_from_direction_flat_line_test wind_from_direction_aggregate"; String ioos_category "Wind"; String platform "platform"; String standard_name "wind_from_direction"; String units "degree"; } wind_from_direction_gross_range_test { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "gross_range_test_quality_flag"; Byte valid_max 9; Byte valid_min 1; } wind_from_direction_spike_test { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "spike_test_quality_flag"; Byte valid_max 9; Byte valid_min 1; } wind_from_direction_rate_of_change_test { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "rate_of_change_test_quality_flag"; Byte valid_max 9; Byte valid_min 1; } wind_from_direction_flat_line_test { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "flat_line_test_quality_flag"; Byte valid_max 9; Byte valid_min 1; } wind_from_direction_aggregate { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "aggregate_quality_flag"; Byte valid_max 9; Byte valid_min 1; } wind_speed { String ancillary_variables "wind_speed_gross_range_test wind_speed_spike_test wind_speed_rate_of_change_test wind_speed_flat_line_test wind_speed_aggregate"; String ioos_category "Wind"; String platform "platform"; String standard_name "wind_speed"; String units "m s-1"; } wind_speed_gross_range_test { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "gross_range_test_quality_flag"; Byte valid_max 9; Byte valid_min 1; } wind_speed_spike_test { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "spike_test_quality_flag"; Byte valid_max 9; Byte valid_min 1; } wind_speed_rate_of_change_test { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "rate_of_change_test_quality_flag"; Byte valid_max 9; Byte valid_min 1; } wind_speed_flat_line_test { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "flat_line_test_quality_flag"; Byte valid_max 9; Byte valid_min 1; } wind_speed_aggregate { String _Unsigned "false"; String flag_meanings "GOOD NOT_EVALUATED SUSPECT BAD MISSING"; Byte flag_values 1, 2, 3, 4, 9; String ioos_category "Quality"; String standard_name "aggregate_quality_flag"; Byte valid_max 9; Byte valid_min 1; } platform { String _Unsigned "false"; String cf_role "timeseries_id"; String ioos_category "Unknown"; } } NC_GLOBAL { String cdm_data_type "TimeSeries"; String cdm_timeseries_variables "platform,longitude,latitude"; String Conventions "COARDS,CF-1.7,IOOS-1.2,ACDD-1.3"; String creator_country "USA"; String creator_email "bullerj@bgsu.edu"; String creator_institution "Bowling Green State University"; String creator_name "BGSU"; String creator_sector "academic"; String creator_type "institution"; String creator_url "https://www.bgsu.edu/news/2012/11/saving-lake-erie.html"; String featureType "TimeSeries"; String geospatial_lat_units "degrees_north"; String geospatial_lon_units "degrees_east"; String gts_ingest "false"; String history "2024-12-03T17:07:54Z (source database) 2024-12-03T17:07:54Z https://seagull-erddap.glos.org/erddap/tabledap/obs_79.html"; String id "obs_79"; String infoUrl "https://www.bgsu.edu/arts-and-sciences/biological-sciences/faculty-and-staff/alphabetical-listing/george-bullerjahn.html"; String institution "BGSU"; String keywords "(fdom), (from), Air, air, at, Battery, battery, Chlorophyll, chlorophyll, concentration, Conductivity, conductivity, depth, direction, Dissolved, dissolved, electrical, fluorescence, Fluorescent, fluorescent, fractional, from, in, mass, matter, of, on, organic, oxygen, period, pH, ph, Phycocyanin, phycocyanin, pressure, reference, reported, saturation, scale, sea, Significant, significant, Specific, speed, surface, temp, temperature, total, Turbidity, turbidity, voltage, Water, water, wave, Wind, wind"; String keywords_vocabulary "GCMD Science Keywords"; String license "The data may be used and redistributed for free but is not intended for legal use, since it may contain inaccuracies. Neither the data contributor, GLOS, NOAA, nor the United States Government, nor any of their employees or contractors, makes any warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, or assumes any legal liability for the accuracy, completeness, or usefulness, of this information."; String naming_authority "org.glos"; String platform "moored_buoy"; String platform_name "Sandusky Bay"; String platform_vocabulary "http://mmisw.org/ont/ioos/platform"; String publisher_country "United States"; String publisher_email "info@glos.org"; String publisher_institution "GLOS"; String publisher_url "https://glos.org"; String sourceUrl "(source database)"; String standard_name_vocabulary "CF Standard Name Table v77"; String summary "The dataset is provided by an YSI EXO-2 water quality sonde installed on a buoy East of the Edison Bridge bisecting Sandusky Bay. The sonde measures parameters important in tracking the intensity of a persistent Planktothrix harmful algal bloom.The purpose of the dataset is to provide a continuous dataset tracking the cyanobacterial bloom in Sandusky Bay. The bloom produces the hepatotoxin microcystin, and measuring the intensity of the bloom will assist in developing models that can help predict bloom intensity."; String title "Sandusky Bay buoy:water quality station"; } }
The URL specifies what you want: the dataset, a description of the graph or the subset of the data, and the file type for the response.
Tabledap request URLs must be in the form
https://coastwatch.pfeg.noaa.gov/erddap/tabledap/datasetID.fileType{?query}
For example,
https://coastwatch.pfeg.noaa.gov/erddap/tabledap/pmelTaoDySst.htmlTable?longitude,latitude,time,station,wmo_platform_code,T_25&time>=2015-05-23T12:00:00Z&time<=2015-05-31T12:00:00Z
Thus, the query is often a comma-separated list of desired variable names,
followed by a collection of
constraints (e.g., variable<value),
each preceded by '&' (which is interpreted as "AND").
For details, see the tabledap Documentation.